ZG(S)-1 Series IC card prepaid gas meter/new gas meter
General
ZG(S)-1 series of IC card prepaid gas meters are suitable for measuring the flowrate of natural gas, liquefied petroleum gas, artificially gas, marsh gas, etc.
The meter has high accuracy measurement and long economic life. Apart from the original reading ability, it also has the following advantages: one particular card for each meter, display of gad volume, reminder of low voltage, protection at low voltage, reminder of insufficient credit, gas overdraft, illegal operation record, switching the valve off while electricity supply is cut off, display button, button to switch on valves, protection of card insert point, anti-magnetic attack, anti-disassembling meter and low power consumption. It is widely used for prepayment management in gas companies. The meter performance can fulfill OIMLR137-1&2 standard requirement.
Main technical parameters | ||||||||
Name
| Aluminum case IC card prepaid gas meter |
| Steel case IC card prepaid gas meter | |||||
Rating working voltage | DC6V | |||||||
Static working current | < 10 μ A |
| < 30 μ A | |||||
Most instantaneous current | < 200 m A |
| < 300 m A | |||||
Impulse constant | 0.1 m3 / impulse or 0.01 m3 / impulse | |||||||
| ||||||||
Specification type | Unit | Type | ||||||
ZG1.6-1 | ZG2.5-1 | ZG1.6S-1 | ZG2.5S-1 | ZG4S-1 | ||||
Nominal flow-rate(Qn) | m3/ h | 1.6 | 2.5 | 1.6 | 2.5 | 4 | ||
Max.flow-rate(Qmax) | m3/ h | 2.5 | 4 | 2.5 | 4 | 6 | ||
Min.flow-rate(Qmin) | m3/ h | 0.016 | 0.025 | 0.016 | 0.025 | 0.04 | ||
Operating pressure range | kPa | 0.5~20 | 0.5~20 | 0.5~50 | 0.5~50 | 0.5~50 | ||
Total pressure loss | Pa | ≤250 | ||||||
Operating temperature | ℃ | -10~+40(special require can reach to -25~+55) | ||||||
Basic error limit |
| 0.1 Qmax≤Q≤Qmax ±1.5% | ||||||
Qmin≤Q<0.1 Qmax ±3% | ||||||||
Max reading | m3 | 99999.999 | 99999.999 | |||||
Connection screw worm (D) |
| M30x2 G13/4” G1” G11/4” | ||||||
Thedistance between connection centers (L) | mm | 130 |
| 130 | 110 | 90 | ||
Weight | kg | 2 | 2.4 |
Technical characteristic
◆ Use 16 bit low power consumption of MCU for intelligent control cell, the logic card for information carrier.
◆ Full-scale function, strong resistance attack, anti-tamper ability.
◆ Use Vale controlling gas, this type of valve is already approved by national authorized organization in anti-riot, action safety, high reliability.
◆ Use 2 types of transmission, collect data credibility.
◆ Strict structure and beautiful appearance.
◆ ZG(S)-1 series meter have one button with multi-function design, easy to operate.
Specification type
Aluminum case: ZG1.6-1, ZG2.5-1
Steel case: ZG1.6S-1, ZG2.5S-1, ZG4S-1